Performance Data Sheet
AJA2416AXA
General Information
Model AJA2416AXA Refrigerant R-12
Test Condition ASHRAE Performance Test Voltage 115V ~ 60HZ
Return Gas 32.2°C (90°F) RETURN GAS Motor Type CSIR
Performance Information
Condensing Temperature (°F)
Evap Temp (°F)
80 90 100 110 120 130 140
Btu/h 1020 743 547 403 286 171 32.2
Watts 453 381 337 313 300 291 277
Amps
-40
Lb/h 23.2 13.8 7.76 4.28 2.37 1.11
Btu/h 1230 964 770 628 513 399 262
Watts 473 406 365 345 335 329 318
Amps
-35
Lb/h 27.9 18.5 12.5 9.05 7.14 5.86 4.28
Btu/h 1450 1190 995 855 742 630 494
Watts 491 428 392 375 369 366 358
Amps
-30
Lb/h 32.3 22.9 16.9 13.4 11.5 10.2 8.60
Btu/h 1680 1410 1220 1090 974 863 729
Watts 508 450 418 405 402 403 398
Amps
-25
Lb/h 36.3 27.0 21.0 17.6 15.6 14.3 12.6
Btu/h 1910 1640 1460 1320 1210 1100 969
Watts 526 472 444 435 436 440 438
Amps
-20
Lb/h 40.3 30.9 25.0 21.5 19.5 18.2 16.5
Btu/h 2140 1880 1700 1560 1460 1350 1220
Watts 544 495 471 466 471 478 480
Amps
-15
Lb/h 44.1 34.8 28.8 25.4 23.4 22.0 20.3
Btu/h 2390 2130 1950 1820 1710 1600 1470
Watts 564 519 501 500 508 519 524
Amps
-10
Lb/h 48.0 38.7 32.7 29.2 27.3 25.8 24.0
Btu/h 2650 2390 2210 2080 1970 1870 1740
Watts 587 547 533 536 549 563 571
Amps
-5
Lb/h 52.0 42.7 36.8 33.3 31.3 29.8 27.9